Slide 1 Slide 2 Slide 3 Slide 4 Slide 5 Slide 6 Slide 7 Slide 8 Slide 9 Slide 10 Slide 11 Slide 12 Slide 13 Slide 14 Slide 15 Slide 16 Product List
Slide9
The impulse speed of the TBU® HSP is shown on this slide. The reaction time on the green current line shows a limit response of 100 ns with a duration of 800 ns. A key feature of the TBU® HSP here is the low 100 nanoJoule let-through energy that passes through to the downstream circuitry. This low energy signal provides opportunities for IC designers to design smaller ICs with lower energy dissipation.  
PTM Published on: 2012-06-07