Current/Voltage Transducer Monitors

Results: 660
Stocking Options
Environmental Options
Media
Exclude
660Results

Showing
of 660
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
34
In Stock
29
Factory
1 : $3,088.32000
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
39
In Stock
1 : $3,186.74000
Box
Box
Active
Voltage Transducer
±1500V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2906242
TRANSDUCER VOLTAGE 24VDC
Phoenix Contact
41
In Stock
1 : $3,842.40000
Bulk
Bulk
Active
Voltage Transducer
±660VDC
±10V
5300VAC (Test)
16ms
-
24VDC
DIN Rail
Screw Terminal
-25°C ~ 60°C
CE, cULus
E83-2050
TRANSDUCER CURRENT 10-40VDC
Carlo Gavazzi Inc.
30
In Stock
1 : $1,593.33000
Bag
Bag
Active
Current Transducer
0 ~ 50A
4 ~ 20mA
-
200ms
±2%
10 ~ 40VDC
DIN Rail
Screw Terminal
-20°C ~ 50°C
CE, UL
CR4510-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
36
In Stock
1 : $1,689.27000
Box
Box
Active
True RMS AC Voltage Transducer
0 ~ 250VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
2813486
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
30
In Stock
166
Factory
1 : $2,961.38000
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
4 ~ 20mA
5000VAC (Test)
340ms
-
20 ~ 30VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
CE, cULus
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
22
In Stock
1 : $3,088.32000
Bulk
Bulk
Active
Current Transducer
0 ~ 200A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 8-28VDC
Verivolt LLC
4
In Stock
1 : $3,186.74000
Box
Box
Active
Voltage Transducer
±500V
±10V
1500V (Working)
2.8µs
±0.2%
8 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
18
In Stock
1 : $3,643.28000
Box
Box
Active
Voltage Transducer
±100V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
23
In Stock
1 : $3,772.85000
Box
Box
Active
Voltage Transducer
±1000V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
3
In Stock
1 : $3,772.85000
Box
Box
Active
Voltage Transducer
±50V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-4C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
9
In Stock
1 : $10,082.35000
Box
Box
Active
Voltage Transducer
±500V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-4C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
5
In Stock
1 : $11,945.84000
Box
Box
Active
Voltage Transducer
±1000V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
DCSA50
TRANSDUCER CURRENT 10-30VDC
Littelfuse Inc.
3
In Stock
1 : $1,645.29000
Bulk
Bulk
Active
Current Transducer
0 ~ 50mA
4 ~ 20mA, 1 ~ 10VDC
Not Isolated
300ms
±0.25%
10 ~ 30VDC
DIN Rail
Screw Terminal
-30°C ~ 60°C
CE, CSA, UL
CR4510-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
18
In Stock
1 : $1,689.27000
Box
Box
Active
True RMS AC Voltage Transducer
0 ~ 500VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
IsoBlock I-FG-1C
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
10
In Stock
1 : $2,580.56000
Box
Box
Active
Current Transducer
0 ~ 6A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2810612
TRANSDUCER CURRENT 24VDC
Phoenix Contact
10
In Stock
1 : $2,689.83000
Bulk
Bulk
Active
Current Transducer
0 ~ 5A
0 ~ 20mA
4000VAC (Test)
-
-
24VDC
DIN Rail
Screw Terminal
-20°C ~ 60°C
ATEX, cULus
IsoBlock I-FG-1C
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
9
In Stock
1 : $2,902.03000
Box
Box
Active
Current Transducer
0 ~ 25A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock I-FG-1C
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
8
In Stock
1 : $2,902.03000
Box
Box
Active
Current Transducer
0 ~ 50A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Screw Terminal, Spring Terminal
-25°C ~ 70°C
-
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
2
In Stock
1 : $2,970.18000
Bulk
Bulk
Active
Current Transducer
0 ~ 100A
0 ~ 10VDC
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
2810625
TRANSDUCER CURR 19.2-253VAC/DC
Phoenix Contact
2
In Stock
1 : $3,120.14000
Bulk
Bulk
Active
Current Transducer
0 ~ 5A
0 ~ 20mA
4000VAC (Test)
200ms
-
19.2 ~ 253VAC/DC
DIN Rail
Screw Terminal
-20°C ~ 65°C
ATEX, cULus
ISOBLOCK V-1C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
16
In Stock
1 : $3,772.85000
Box
Box
Active
Voltage Transducer
±300V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
10
In Stock
1 : $3,772.85000
Box
Box
Active
Voltage Transducer
±750V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
2
In Stock
1 : $3,842.24000
Bulk
Bulk
Active
Current Transducer
0 ~ 600A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-
24VDC
Chassis Mount, DIN Rail
Spring Terminal
-40°C ~ 65°C
CE, cULus
IsoBlock I-FG-4C
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
12
In Stock
1 : $9,246.56000
Box
Box
Active
Current Transducer
0 ~ 6A
±10V
1200V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
Showing
of 660

Current/Voltage Transducer Monitors


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.